The HAMILTON C3 ventilator is a premium solution for all patient populations. With its unique features, the HAMILTON C3 is one of the first ventilators to offer "automated ventilator" capability through INTELLiVENT®ASV®. Its compact design combined with a compressed air system that operates independently of a central gas supply allows the ventilator to run at full performance throughout intrahospital transport.
Automated control of ventilation and oxygenation status with INTELLiVENT®ASV® mode
P/V Tool Pro for lung recruitment and derecruitment assessment
High flow oxygen therapy
High performance NIV
Compact design with an internal compressor operating independently of a central air supply
For adult, pediatric, and neonatal patients
Also available in: Tiếng Việt
KEY TECHNICAL FEATURES
Integrated internal turbine for high pressure air generation
Peak flow up to 240 L/min
Automatic leak compensation function (IntelliTrig)
Tube Resistance Compensation (TRC)
Dynamic Lung display: real time animated lung visualization
Vent Status display (visualization of patient ventilation status): weaning assessment
On screen troubleshooting assistance
Lung recruitment and optimal PEEP assessment tool (P/V Tool Pro)
VENTILATION MODES
Volume Controlled Mandatory Ventilation ((S)CMV)
Synchronized Intermittent Mandatory Ventilation with volume control (SIMV)
Volume controlled mandatory ventilation with automatic pressure adaptation (APVcmv / (S)CMV+)
Synchronized intermittent mandatory ventilation with volume control and automatic pressure adaptation (APVsimv / SIMV+)
Pressure Controlled Ventilation (PCV+)
Pressure Controlled Synchronized Intermittent Mandatory Ventilation (PSIMV+)
Dual Positive Airway Pressure (DuoPAP)
Airway Pressure Release Ventilation with inverse ratio (APRV)
Spontaneous mode (SPONT)
Adaptive Support Ventilation (ASV)
Intelligent Adaptive Support Ventilation (IntelliVENT ASV)
Noninvasive Ventilation (NIV)
Noninvasive Ventilation with Backup Rate (NIV ST)
High Flow Oxygen Therapy mode (HiFlowO2)
MONITORED PARAMETERS
LUNG MECHANICS
Cstat (ml/cmH2O): Dynamic compliance
P0.1 (cmH2O): Airway occlusion pressure
PTP (cmH2O*sec): Pressure time product
RCexp (sec): Expiratory time constant
Rinsp (cmH2O/(L/sec)): Inspiratory resistance
RSB (1/(L*min)): Rapid shallow breathing index
PRESSURE
AutoPEEP (cmH2O): Intrinsic positive end expiratory pressure
Paw (cmH2O): Airway pressure
PEEP/CPAP (cmH2O): Positive end expiratory pressure / continuous positive airway pressure
Pinsp (cmH2O): Inspiratory airway pressure
Pmean (cmH2O): Mean airway pressure
Ppeak (cmH2O): Peak airway pressure
Pplateau (cmH2O): Plateau pressure
VOLUME
ExpMinVol or MinVol NIV (L/min): Expiratory minute ventilation
MVSpont or MVSpont NIV (L/min): Spontaneous expiratory minute ventilation
VTE or VTE NIV (ml): Expiratory tidal volume
VTESpont (ml): Spontaneous breath expiratory tidal volume
VTI or VTI NIV (ml): Inspiratory tidal volume
Vt/IBW: Tidal volume per ideal body weight (IBW) for adult and pediatric patients
Vt/Weight (ml/kg): Tidal volume per actual body weight for neonatal patients
VLeak (%): Leak volume as a percentage
MVleak (L/min): Total leak volume per minute
FLOW
Insp Flow (L/min): Maximum peak inspiratory flow of a spontaneous or mandatory breath
Exp Flow (L/min): Peak expiratory flow
Flow (L/min): Flow delivered to the patient in flow controlled mode
TIME
I:E: Inspiratory to expiratory time ratio
fControl (breaths/min): Mandatory respiratory rate
fSpont (breaths/min): Spontaneous respiratory rate
fTotal (breaths/min): Total respiratory rate
TI (sec): Inspiratory time
TE (sec): Expiratory time
Pause (sec): Inspiratory hold time (plateau)
CO2 MONITORING
FetCO2 (%): End tidal carbon dioxide concentration
PetCO2 (mmHg): End tidal carbon dioxide partial pressure
slopeCO2 (%CO2/L): Slope indicating alveolar pressure on the PetCO2 curve, reflecting lung volume/flow status
Vtalv (ml): Alveolar tidal volume
V'alv (L/min): Alveolar minute ventilation
V'CO2 (ml/min): Expired carbon dioxide flow
VDaw (ml): Airway dead space
VDaw/VTE (%): Ratio of dead space at the patient wye connector to VTE
VeCO2 (ml): Expired CO2 volume
ViCO2 (ml): Inspired CO2 volume
SPO2 MONITORING
SpO2 (%): Blood oxygen saturation (numeric value)
Plethysmogram: SpO2 waveform
Pulse (beats/min): Heart rate
SpO2/FiO2 (%): SpO2/FiO2 ratio, approximating the PaO2/FiO2 ratio but measurable noninvasively and continuously
PI (%): Perfusion index
PVI (%): Pleth variability index
SpCO (%): Carboxyhemoglobin saturation
SpHb (g/dl) (mmol/l): Methemoglobin saturation
SpOC (ml/dl): Oxygen content
DATA STORAGE CAPACITY
Trend display (1 to 72 hours) & Loop display (Pressure/Volume, Pressure/Flow, Volume/Flow, Volume/PCO2, Volume/FCO2)
Event log (up to 1,000 events with date and time stamps)